SIERRA CONTROLLERS
Part Number | Nominal Voltage | Description | Compressor Models | Controller Drawing | Wiring Diagram | Manual Control Device | Comp. Harness | UL | CE |
---|---|---|---|---|---|---|---|---|---|
025F0095 | 12-24 VDC | 9-30 VDC | SIERRA02-0434XX | DGMX0022 CAD FILE |
DEMX0020 | 030A0117 | 040F0248 | YES | YES |
025F0219 | 12-24 VDC |
Flanged Heatsink 9-30 VDC |
DGMX0055 CAD FILE |
DEMX0020 | 030A0117 | 040F0248 | YES | YES | |
025F0200 | 12-24 VDC | 9-30 VDC | SIERRA02-0716XX | DGMX0022 CAD FILE |
DEMX0020 | 030A0117 | 040F0248 | YES | YES |
025F0218 | 12-24 VDC |
Flanged Heatsink 9-30 VDC |
DGMX0055 CAD FILE |
DEMX0020 | 030A0117 | 040F0248 | YES | YES | |
025F0348 | 12-24 VDC |
*Dual 9-30 VDC |
DGMX0022 CAD FILE |
DEMX0033 | 030A0117 | 040F0248 | YES | YES | |
025F0149 | 24-48 VDC |
Flanged Heatsink 20-57 VDC |
SIERRA03-0434XX SIERRA03-0716XX SIERRA03-0982XX |
DGMX0031 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES |
025F0349 | 24-48 VDC | Flanged Heatsink, Soft Start 20-57 VDC | DGMX0031 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES | |
025F0129 | 24-48 VDC | 20-57 VDC | DGMX0033 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES | |
025F0350 | 24-48 VDC | Soft Start, 20-57 VDC | DGMX0033 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES | |
025F0216 | 24-48 VDC | *Flanged Heatsink, Dual 20-57 VDC | DGMX0031 CAD FILE |
DEMX0023 | 030A0043 | 040F0250 | YES | YES | |
025F0158 | 48 VDC |
Flanged Heatsink 38-57 VDC |
SIERRA04-0434XX SIERRA04-0982XX SIERRA17-0434XX SIERRA17-0982XX |
DGMX0031 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES |
025F0152 | 48 VDC | 38-57 VDC | DGMX0033 CAD FILE |
DEMX0010 | 030A0043 | 040F0250 | YES | YES | |
025F0164 | 80 VDC |
Flanged Heat sink 60-97 VDC |
DGMX0051 CAD FILE |
DEMX0021 | 030F0234 | 040F0248 | NO | NO | |
025F0139 | 80 VDC | 60-97 VDC | DGMX0042 CAD FILE |
DEMX0021 | 030F0234 | 040F0248 | NO | NO | |
025F0202 | 80 VDC | *Dual, 60-97 VDC | CAD FILE | DEMX0032 | 030F0234 | 040F0248 | NO | NO | |
025F0391 | 100 VDC |
Flanged Heatsink 55-110 VDC |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO | |
025F0393 | 100 VDC |
Flanged Heatsink 75-125 VDC |
SIERRA04-0434XX SIERRA04-0982XX SIERRA05-0434XX SIERRA05-0982XX |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO |
025F0394 | 110 VDC |
Flanged Heatsink 70-145 VDC |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO | |
025F0395 | 100-150 VDC |
Flanged Heatsink 90-165 VDC |
SIERRA05-0434XX SIERRA05-0982XX |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO |
025F0396 | 100-150 VDC |
Flanged Heatsink 90-260 VDC |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO | |
025F0397 | 150-300 VDC |
Flanged Heatsink 115-325 VDC |
SIERRA06-0434XX SIERRA06-0982XX |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO |
025F0398 | 150-300 VDC |
Flanged Heatsink 120-420 VDC |
DGMX0095 CAD FILE |
DEMX0006 | 030A0138 | 040F0268 | NO | NO | |
025F0401 | 150-300 VDC |
‡Flanged Heatsink, Dual, 120-420 VDC |
DGMX0095 CAD FILE |
DEMX0034 | 030A0138 | 040F0268 | NO | NO | |
025F0405 | 600 VDC |
Flanged Heatsink 470-750 VDC |
SIERRA10-0982XX | DGMX0097 CAD FILE |
DEMX0044 | 030A0138 | 040F0270 | NO | NO |
025F0248 | 600 VDC |
‡Flanged Heatsink, Dual 470-750 VDC |
DGMX0054 CAD FILE |
DEMX0041 | 030A0138 | 040F0270 | NO | NO |
Masterflux Resistor Calculator Tool
* Requires the use of a cross-over cable for dual compressor operation: p/n 040A0162
‡ Requires the use of a cross-over cable for dual compressor operation: p/n 872F0007
CASCADE CONTROLLERS
Part Number | Nominal Voltage | Description | Compressor Models | Controller Drawing | Wiring Diagram | UL | CE |
---|---|---|---|---|---|---|---|
030F0121 | 12-24 VDC | Compressor Mounted Controller 9.6-31.5 VDC | CASCADE17-XXXXY1 | DGMX0044 CAD FILE | DEMX0024 | YES | NO |
030F0137 | 48 VDC | Compressor Mounted Controller 36-60 VDC | CASCADE17-XXXXY1 CASCADE17-XXXXY3 | DGMX0050 CAD FILE | DEMX0028 | YES | YES |
030F0152 | 24 VDC | Compressor Mounted Controller 19-30 VDC | CASCADE17-XXXXY3 | DGMX0050 CAD FILE | DEMX0028 | NO | NO |
030F0175 | 48 VDC | Compressor Mounted Controller 36-60 VDC, Flat Heatsink | CASCADE17-XXXXY1 CASCADE17-XXXXY3 | DGMX0082 CAD FILE | DEMX0028 | NO | NO |
030F0176 | 24 VDC | Compressor Mounted Controller 19-30 VDC, Flat Heatsink | CASCADE17-XXXXY3 | DGMX0082 CAD FILE | DEMX0028 | NO | NO |
MESA and ATLAS CONTROLLERS
Part Number | Nominal Voltage | Description | Compressor Models | Controller Drawing | Wiring Diagram | Manual Function Control | Comp. Harness | Signal Harness | UL | CE |
---|---|---|---|---|---|---|---|---|---|---|
025F0440 | 12 VDC | 9-20 VDC | MESA01-0122Y3 | DGMX0100 CAD FILE |
DEMX0066 | N/A | N/A | N/A | NO | YES |
025F0441 | 24 VDC | 16-32 VDC | MESA18-0122Y3 | DGMX0101 CAD FILE |
DEMX0066 | N/A | N/A | N/A | NO | YES |
025F0433 | 24 VDC |
18-31.5 VDC w/ Enclosure |
ATLAS18-0444Y4 | DGMX0091 CAD FILE | DEMX0060 | 025F0377 | 040F0276 | 040F0278 | NO | NO |
025F0407 |
12 VDC 24 VDC 48 VDC |
9.6-17.0 VDC 19.0-31.5 VDC 32.5-60.0 VDC w/ Enclosure |
ATLAS18-0444Y4 | DGMX0091 CAD FILE | DEMX0060 | 025F0377 | 040F0276 | 040F0278 | NO | NO |